Digital Flame Photometers |
|
|
We offer wide range of digital flame photometers with fitted (Na & K) 3½ digit LED display (ppm) along with compressor and other accessories Ca & Li filter can be provided on request.
|
 |
 | Microprocessor Flame Photometer |  | 
 | Item Code: LT-671 Four Element measurement in a single aspiration (Na, K, Li and Ca).
Calibration curve fit routines first order and second order.
Data displayed in concentration units i.e. ppm & meq, automatic filter selection; auto calibration feature. Printer attachment, PC connecting compatibility, Sample data storage more than 500 results. Alphanumerical key board for easy data entry. Graphical LCD display thus easy to read, Curve calibration using upto 5 standard, Multiple calibration curve saving facility, Stanless steel burner.
Auto Gas Cut off in case of power failure.
Ca & Li Filters Extra on Request Only.
Other Information - Pay Mode Terms: L/C (Letter of Credit), D/A (Documents Against Acceptance), D/P (Documents Against Payment), T/T (Bank Transfer), Western Union, Other
- Minimum Order Quantity: 1 Piece/Pieces
- Port of Dispatch: NEW DELHI
- Production Capacity: 100 UNITS PER MONTH
- Delivery Time: 08 DAYS
- Packaging Details: EXPORT WORTHY
|

 | Item Code: LT-65 We are a reckoned enterprise, which is engaged in delivering Photometer to the clients. The offered range is made utilizing optimum grade raw material and innovative technology in strict conformation with the international quality norms and standards. Along with this, the offered range is suitably checked on different characteristics to maintain its authenticity throughout the designing process. Features: - High performance
- Durable
- Superior efficiency
- Reliable operations
| LT-65 | Digital Flame Photometer | With fitted (Na & K) 3½ digit LED display (ppm) along with compressor and other accessories Ca & Li filter can be provided on request. | | LT-66 | Digital Clinical Flame Photometer | Dual channel single aspiration with filter (Na & k) for medical use. Final result in meq/L 2½ digit dual LED display for simultaneous results along with compressor & accessories . | | LT-67 | Microprocessor flame photometer | With Sodium (Na) and Potassium (K) filters, upto 5 points calibration, direct readout in pp, & meq/l, auto filter selection, auto ignition, 24 x 4 line LCD display, Single Aspiration, RS232 interface, printer attachments facility, with compressor and other accessories for lab & medical use. Ca & Li Fileres and optional at extra cost. |
|
 | Digital Flame Photometers |  |  | Item Code: LT-65_LT-66 We offer wide range of Digital Flame Photometers with following specifications. Specifications | Model | LT-65(Digital Flame Photometer) | LT-66(Digital Clinical Flame Photometer) | | No. of Filters | Na & K (Ca & Li optional) | Na & K (Ca & Li optional) | | Range | Na: 0-100 ppm Ca: 20-100 ppm K : 0-100 ppm Li: 10-100 ppm | Na: 0-200 meq/l Ca: 0-2 meq/l K : 0-100 meq/l Li: 0-10 meq/l | | Sensitivity | Na: 5 ppm Ca: 10 ppm K : 5 ppm Li: 10 ppm | Na: 5 pmm Ca: 10 ppm K : 5 pmm Li: 10 ppm | | Display | 2 1/2 digit bright LED Display | Dual 2 1/2 digit bright LED Display | | Accuracy | + 2% upto 40 ppm + 5% above 40 ppm | + 2% upto 100 meq/l + 5% above 100 meq/l | | Repeatability | + 2 Count | + 2 Count | | Detector | Silicon Photodiode | Silicon Photodiode | | Filters | Narrow band interference glass filters | Narrow band interference glass filters | | Nebulizer | Black bakelite, axial flow type | Black bakelite, axial flow type | | Flame System | LPG and dry oil free air | LPG and dry oil free air | | Warmup time | 10 minutes | 10 minutes | | Power | 230V + 10% AC 50 Hz | 230V + 10% AC 50 Hz | | Size (LxBxH) | 355 x 250 x 210 mm | 455 x 250 x 210 mm | | Weight | 6.5 kg (Approx.) | 7.5 kg (Approx.) | | Compressure Unit | | Air Supply | By Oil free mini compressor unit with pressure regular | | Combustion | LPG controlled by precision regulator | | Power | 230V +10% AC 50 Hz | | Size (LxBxH) | 275 x 192 x 240 mm | | Weight | 9 Kg (Approx.) | | Accesspries | Instrument with Na & K Filters, Instruction Manual, Dustcover, Chimney, Air Tubing |
|
 | Microprocessor Flame Photometer |  |  | Item Code: LT-67 We offer wide range of Microprocessor Flame Photometer with following specifications. Specifications | Mode | General | Serum | Urine | | Range | Na: 0.1-100 ppm Upto 250 meq/l, 1:100 dil
K: 0.1-100 ppm Upto 250 meq/l, 1:100 dil
Ca: 15-100 ppm Upto 250 meq/l, 1:100 dil
Li: 0.5-100 ppm Upto 250 meq/l, 1:100 dil | Na: 0-200 1:100 dil
K: 0-10 1:100 dil
Ca: - Li: 0-2 1:5 dil | Na: 0-250 1:100 dil
K: 0-100 1:100 dil
Ca: - Li: 0-10 1:2 dil | | Sensitivity | General Mode: Na:0.5 ppm, K:0.5 ppm, Li:0.5 ppm, Ca:15 ppm | | Filters | Na & K Supplied (Ca & Li are optional at extra cost) | | Resolution | 0.1 ppm/meq | | Reproducibility | + 2% FS, &± 2 Digits | | Curve Fit Accuracy | + 2% FS | | Display | 20 x 4 Alphanumeric backlit LCD display | | Average Time | In-built in Software | | Flame System | LPG & dry oil free air | | Detector | Silicon Photodiode | | Calibration | Upto 5-Point Calibration with curve fitting software | | Gas Control | Adjustable with knobs | | Ignition System | Auto Ignition | | Automiser | Axial flow type | | RS-232C Interface | Available (PC Software at extra cost) | | Power | 230 V + 10% AC, 50 Hz | | Dimensions | 365 x 245 x 220 mm (L x B x H) (Approx.) | | Weight | Main Unit : 7.5 Kg. (Approx.) | | COMPRESSOR UNIT | | Air Supply | By oil free mini compressor unit with pressure regulator | | Combustion Gas LPG | Controlled by precision regulator | | Power | 230 V + 10% AC, 50 Hz |
|
|
|